The Harmonizer
Programmer’s Manual
The Harmonizer
Programmer’s Manual Page 51 of 97 Release 1.2.1
1999 Eventide, Inc.
• The “%%” in the menu statement is necessary to allow a single “%” symbol to appear on the
Harmonizer’s display. This is because “%” is a special symbol that tells the Harmonizer that numeric
information is to be displayed in what follows. Thus, to tell it that you actually want to display a “%”
symbol requires two.
Depth
Add a knob module and connect its control
output to
gain2 on the mixer module. Then
double click on it to alter its specifiers to match
those shown to the right.
• The control inputs on the mixer module
accept values from -100 to zero.
Rate
Add a knob module and connect its control
output to
freq on the LFO module. Then double
click on it to alter its specifiers to match those
shown to the right.
• The
freq control input on the LFO module
accepts a value between zero and 1000.