RFL Single Pair
Use the RFL Single Pair hookup when only one wire
in a pair is faulted and a separate good pair is not
available.
Use the Separate Pair hookup for all cases in
which a separate pair is available; it is always the
preferred method.
You must first use the Ohms function to identify
a faulted conductor in a pair and to verify that the
other conductor is not faulted.
Once you identify the wires, strap the faulted and
good conductor together at the far-end.
Press the [RFL] key and select “Single pair” using
the [Tab] key.
Verify correct wire gauge and temperature. Use the
[Setup] key to change the gauge or temperature.
Connect the red test lead to the faulted conductor
in the pair. Connect the green test lead to the good
conductor of the same pair. Connect the black Lead
to the reference. (The reference wire could be the
shield or another wire in the cable.)
Press the [Enter] key after you have made the above
connections. If the connections are OK, the 965DSP
will go directly to the RFL results screen.