:COMMunicate
:SERial[n] [:RECeive]
:BITS
SYSTem:COMMunicate:SERial[n][:RECeive]:BITS < bits> Sets the number
of bits to be used to transmit and receive data.
Parameters Parameter
Name
Parameter
Type
Range of
Values
Default
Units
bits numeric 7| 8| MIN| MAX none
Comments Attempting to set bits to other than those values shown will result in an
error -222.
While this command operates independently of either the
PARity:TYPE or SBITs commands, there are two combinations
which are disallowed because of their data frame bit width. The following
table shows the possible combinations:
BITS PARity:TYPE SBITs Frame Bits
7 NONE 1 9 - disallowed
7NONE2 10
7Yes110
7Yes211
8NONE1 10
8NONE2 11
8Yes111
8 Yes 2 12 - disallowed
DIAG:BOOT:COLD will set BITS to 8.
Related Commands: SYST:COMM:SER[n]:PARity
*RST Condition: No change
Example Configuring data width to 7 bits.
SYST:COMM:SER0:BITS 7
:COMMunicate
:SERial[n] [:RECeive]
:BITS?
SYSTem:COMMunicate:SERial[n][:RECeive]:BITS? [MIN | MAX] returns:
The current data width if no parameter is sent.
The maximum allowable setting if MAX is sent.
The minimum allowable setting if MIN is sent.
Example Querying the current data width.
SYST:COMM:SER0:BITS?
enter statement statement enters 7 or 8
SYSTem:COMMunicate :SERial[n] [:RECeive] :BITS