:COMMunicate
:SERial[n] [:RECeive]
:SBITs?
SYSTem:COMMunicate:SERial[n][:RECeive]:SBITs? [MIN | MAX] returns:
The current stop bit setting if no parameter is sent.
The maximum allowable setting if MAX is sent.
The minimum allowable setting if MIN is sent.
Example Querying the current stop bit configuration.
SYST:COMM:SER0:SBITs? :REC is implied
enter statement statement enters 1 or 2
:COMMunicate
:SERial[n] :TRANsmit
:AUTO
SYSTem:COMMunicate:SERial[n]:TRANsmit:AUTO < auto_cntrl> when
ON, sets the transmit pacing mode to be the same as that set for receive pacing.
When OFF, the transmit pacing mode may be set independently of the receive
pacing mode.
Parameters Parameter
Name
Parameter
Type
Range of
Values
Default
Units
auto_cntrl boolean 0| 1| OFF| ON none
Comments For an Agilent E1324A, AUTO is always ON. Trying to set OFF or 0 will
generate an error.
DIAG:BOOT:COLD will set AUTO to ON.
Related Commands: SYST:COMM:SER[n]:REC:PACE:PROT,
SYST:COMM:SER[n]:TRAN:PACE:PROT
*RST Condition: TRAN:AUTO ON
Example Link transmit pacing with receive pacing
SYST:COMM:SER0:TRAN:AUTO ON
:COMMunicate
:SERial[n] :TRANsmit
:AUTO?
SYSTem:COMMunicate:SERial[n]:TRANsmit:AUTO? returns the current
state of receive to transmit pacing linkage.
Comments For an Agilent E1324A, AUTO is always ON. In this case AUTO? will
always return a 1.
Example Is AUTO ON or OFF?
SYST:COMM:SER0:TRAN:AUTO?
enter statement statement enters the number 1
or 0
SYSTem :COMMunicate :SERial[n] [:RECeive] :SBITs?