Agilent Technologies E1301B Computer Hardware User Manual


 
Agilent E1332A 4-Channel Counter/Totalizer Menu
Menu Levels and Content
Level 1 Level 2 Level 3 Level 4 Level 5 User Entry Command(s) Used Description
COUNTER MONITOR CHAN1 DISP:MON:CHAN 1;STAT ON Monitor instrument operations on channel 1
CHAN2 DISP:MON:CHAN 2;STAT ON Monitor instrument operations on channel 2
CHAN3 DISP:MON:CHAN 3;STAT ON Monitor instrument operations on channel 3
CHAN4 DISP:MON:CHAN 4;STAT ON Monitor instrument operations on channel 4
AUTO DISP:MON:CHAN AUTO;STAT ON Monitor instrument operations on active channel
INPUT LEVEL CHAN1&2 voltage † SENS1:EVEN:LEV <value> Set level trigger voltage for channels 1 & 2
CHAN3&4 voltage † SENS3:EVEN:LEV <value> Set level trigger voltage for channels 3 & 4
SLOPE CHAN1 POS SENS1:EVEN:SLOP POS Positive level tr igger slope for channel 1
NEG SENS1:EVEN:SLOP NEG Negative level trigger slope for channel 1
CHAN2 POS SENS2:EVEN:SLOP POS Positive level trigger slope for channel 2
NEG SENS2:EVEN:SLOP NEG Negative level trigger slope for channel 2
CHAN3 POS SENS3:EVEN:SLOP POS Positive level trigger slope for channel 3
NEG SENS3:EVEN:SLOP NEG Negative level trigger slope for channel 3
CHAN4 POS SENS4:EVEN:SLOP POS Positive level trigger slope for channel 4
NEG SENS4:EVEN:SLOP NEG Negative level trigger slope for channel 4
ISOLATE ON INP:ISOL ON Input isolation on
OFF INP:ISOL OFF Input isolation off
FILTER ON INP:FILT ON Input filter on
OFF INP:FILT OFF Input filter off
FREQ frequency ‡ INP:FILT:FREQ <value> Set input filter frequency
FREQ CHAN1 TRIG:SOUR IMM;:MEAS1:FREQ? Frequency measurement on channel 1
CHAN3 TRIG:SOUR IMM;:MEAS3:FREQ? Frequency measurement on channel 3
PERIOD CHAN1 TRIG:SOUR IMM;:MEAS1:PER? Period measurement on channel 1
CHAN3 TRIG:SOUR IMM;:MEAS3:PER? Period measurement on channel 3
(continued on following page)
2-24 Using the Display Terminal Interface