Table 1-1 Agilent Z5623A Option H48 Guaranteed Performance Specs
Parameter Specification
Frequency Range 300 kHz to 9.0 GHz
Crosstalk
a
1) –110 dB
b
2) –105 dB
c
3) –95 dB
d
4) –90 dB
e
Return Loss (port active)
f
1) 24 dB
b
2) 18 dB
c
3) 14 dB
d
4) 9 dB
e
Return Loss (port off)
g
1) 26 dB
b
2) 20 dB
c
3) 16 dB
d
4) 14 dB
e
Insertion Loss
h
1) 1.5 dB
b
2) 2.0 dB
c
3) 2.5 dB
d
4) 3.5 dB
e
Switch Lifetime 5 million cycles
Maximum Input Power
1 Watt (RF + DC)
i