Configuring an E1 Port
Page 33-8
Configuring an E1 Port
The temod command configures an E1 port at the physical level and is generic to all such
ports regardless of the logical level service, such as circuit emulation, that controls them. You
configure the circuit emulation service that controls this port through the cemodify command.
To configure an E1 port, enter the following command
temod <slot>/<port>
where <slot> is the slot number where the board is located, and <port> is the T1 port number
on the board that you want to modify. For example, to modify port number 2 on the board in
switch slot 4, you would enter
temod 4/2
A screen similar to the following displays:
E1 Port Configuration for slot 4, port 2
1) Circuit Identifier (30 chars max) : Alcatel E1 Circuit
2) Frame Format { E1 (4), E1-CRC (5), E1-MF (6),
E1-CRC-MF (7), unframed (9) } : E1
3) Not FAS { enabled (1), disabled (2) } : enabled
4) Line Build Out { short(1), long(2) } : short
40) Cable Type { 75 Ohm (1), 120 Ohm (2) } : 75 Ohm
5) Line Coding { HDB3 (3), AMI (5) } : HDB3
6) Transmit Clock Source { loopTiming (1),
localTiming (2) } : localTiming
7) Loopback Mode { none (1), payload (2), line (3),
inward (5) } : none
8) Signalling { none (1), CAS (2), CCS (3) } : none
9) Trap Generation { enabled (1), disabled (2) } : disabled
Enter (option=value/save/cancel) :
1) Circuit Identifier
Enter a textual description of this E1 port, up to 30 characters. This text will be used in other
screen displays to identify this E1 port.