Allied Telesis AT-WA7501 Network Card User Manual


 
Chapter 3: Configuring the Ethernet Network
88
2. Configure the filter expressions parameters. For help, see the next
table.
3. Click Submit Changes to save your changes. To activate your
changes, from the menu bar click Save/Discard Changes, and then
click Save Changes and Reboot. For help, see “Saving Configuration
Changes” on page 46.
Table 21. Filter Expressions Parameter Descriptions
Parameter Explanation
ExprSeq
(Expression
Sequence)
Indicates the order in which the filters will be
executed. When you change the parameter, the
statements are reordered and renumbered so the
Expression Sequence order is maintained. The
range is from 0 to 255.
This parameter works with the Action parameter;
for example, if the action is set to And, then the
next sequence in another expression is
processed.
Offset Identifies a point inside the frame where testing
for the expression is to start. The range is from 0
to 65535.