Allied Telesis AT-X510DP-52GTX Switch User Manual


 
x510DP-52GTX Installation Guide
79
Note
The User Exec mode is the first level in the command mode
interface. For complete information on the modes and commands,
refer to the Software Reference: AlliedWare Plus Operating System
for x510 Series.
3. Enter the SHOW STACK command to display the status of the
VCStack feature. Figure 40 is an example of the command.
Figure 40. SHOW STACK Command
4. Review the following items:
If the Operational Status is “Stacking Hardware Disabled,” the
VCStack feature is already disabled on the switch and the SFP+
stacking slots may be used with regular SFP or SFP+ transceivers.
If the Operational Status is “Standalone Unit,” as shown in Figure
40 on page 79, the VCStack feature is active on the unit. You must
disable it by performing the steps in the rest of this procedure
before you can use the SFP+ stacking slots with regular SFP or
SFP+ transceivers. The reason the status says “standalone” is
because the switch considers itself a stack of one switch.
5. Move to the Global Configuration mode by entering the ENABLE and
CONFIGURE TERMINAL commands, as shown in Figure 41.
Figure 41. Moving to the Global Configuration Mode
6. To. disable the VCStack feature on the switch, enter the NO STACK
ENABLE command, which has this format:
no stack
id
enable
awplus> show stack
Virtual Chassis Stacking summary information
ID Pending ID MAC address Priority Status Role
1 - 0015:774f:ed30 128 Ready Active Master
Operational Status Standalone Unit
Stack MAC address 0015:774f:ed30
awplus(config)#
awplus> enable
awplus# configure terminal
Enter configuration commands, one per line. End with CNTL/Z
awplus(config)#