AMX UDM-0404 Switch User Manual


 
Installation
5
UDM-0404 Endeleo Multi-Format Distribution Hub
Installation
Overview
The UDM-0404 occupies a single rack space in a standard 19" equipment rack. Rack-mounting brackets
and screws are located in the accessories box supplied with the UDM-0404.
1. Attach the rack-mounting brackets to each side of the UDM-0404 using four M4 screws for each
bracket (FIG. 2).
2. Place the UDM-0404 in the rack and hold steady.
3. Two fixing holes are supplied on each side of the UDM-0404. Secure the UDM-0404 into the rack
using the fixing holes (FIG. 3).
Ventilation
ALWAYS ensure that the rack enclosure is adequately ventilated.
Sufficient airflow must be achieved (by convection or forced-air cooling) to satisfy the ventilation
requirements of all the items of equipment installed within the rack.
Exercise extreme care when lifting or moving the UDM-0404 within the rack to avoid
injury. It is recommended that you seek the assistance of another person when rack
mounting the 0404.
FIG. 2 Attach the mounting brackets to each side of the UDM-0404
To prevent injury the UDM-0404 must be securely attached to the rack in accordance
with the installation instructions.
ALWAYS use the special rack mount brackets supplied and high quality fixing screws
to ensure the UDM-0404 is installed in the rack correctly.
FIG. 3 Secure the UDM-0404 into the rack using the fixing holes
DO NOT stand other units directly on top of the UDM-0404 when it is rack mounted,
as this will place excessive strain on the mounting brackets.