Avocent ACS 6000 Server User Manual


 
WARNING: Itiscriticalthatthe power sourcesupportstheDC power requirementsofyour consoleserver.Make
surethatyour power sourceisthecorrecttypeandthat yourDC power cablesare ingoodconditionbefore
proceeding.Failuretodosocouldresultinpersonalinjuryordamageto theequipment.
The following diagram shows the connector configuration for DC power.
Figure 2.4: DC Power Connection Terminal Block
Number Description Number Description
1 Powerswitch 3 GND (Ground)
2 RTN (Return) 4 -48VDC
Table 2.6: DC Power Connection Details
1. Make sure the console server is turned off.
2. Make sure DC power cables are not connected to a power source.
3. Remove the protective cover from the DC power block by sliding it to the left or right.
4. Loosen all three DC power connection terminal screws.
5. Connect your return lead to the RTN terminal, your ground lead to the GND terminal and
your -48 VDC lead to the -48 VDC terminal and tighten the screws.
6. Slide the protective cover back into place over the DC terminal block.
7. If your console server has dual-input DC terminals, repeat steps 3-6 for the second terminal.
8. Connect the DC power cables to the DC power source and turn on the DC power source.
Chapter 2: Installation 13