Barco R9010342 Projector User Manual


 
6. Advanced
video signal
video signal
frame blanking
HI
egalisation
Image 6-94
HI AGC Hold interval
The Comb lter is by default enabled.
The AGC hold interval is the time interval in which the AGC is inhibited (AGC hold = no update in video amplitude measurement),
the advanced parameter allows to choose a short or long hold interval.
A long AGC hold interval eliminates Macrovision
®
disturbances since the AGC is hold during a lo
ng interval, thus reducing the
probability to encounter a Macrovision
®
pulse.
The sync locking setting is recommended for poor video signals (ex: poor TV signals).
Sharpness adjustment can be chosen to be coarse or ne.
It is recommended to use the default values.
Advanced Data settings
The advanced button enables the advanced settings for a data source.
Image 6-95
video info
a
Hs Hs
b
Image 6-96
Hs horizontal sync pulse
aactivelow
b active high
The VCO range setting determines the frequency range of the VCO (Voltage Controlled Oscillator).
The Cpmp (Charge pump current) sets the low pass lter current.
Both VCO range & Cpmp are set by the image le, changing these settings is only indicated in for special purposes.
The horizontal sync polarity setting can be useful in case of a bad shaped edge, one can choose between the leading (active low)
or trailing (active high) edge.
The input format settings are used to "tell more" about the signals connected on the BNC’s, it completes the information in the source
selection menu.
- RGB is selected by default and means that an RGB signal is connected to the BNC’s
- PR/Y/PB must be selected whenever:
92