6. Web Interface
Image 6-42
Manage system configuration
The content of the Configuration tab is display ed.
3. To download a full back up, click on Download Full Backup (3).
An xml file, containing all information and history will be do wnloaded. This file can be r eused on the s ame Base Unit only.
4. To download a portable version, click on Download Portable Version (4).
An xml file, containing portable information to duplicate settings on anoth er Base Unit.
5. To upload a configuration, click on Upload Configuration (5).
A browser window opens. Navigate to the upload file (xml file) and click Open to upload.
When uploading a config file, the history of software updates and paired dongles is lost. Paired dongles will
however rem ain functional if the Base Unit has not chan ge d f rom SSID or w ireless password.
6.26 Load Default Settings
About default settings
The ClickShare Base Unit can return to the factory default settings.
The following s ettings are the defaults:
• Meeting room identification info is cleared.
• Language is set to English.
• Custom wallpapers are removed and the default wallpaper is restored.
• Display resolution is set to auto and standby timer is reset to infinity
• Display Identifiers are turne d off.
• Hostname and S SID is s et to click share-serialnumber.
• The SSID is broadcasted
• WiFi password is reset to clickshare.
• The default WiFi channel is set back to frequency 2.4 GHz, channel 6.
• The update history is cleared.
• The table with the associated Buttons is cleared.
• The admin password is reset to admin.
• Debug lo gging and remote logging are disabled.
68
R5900004 CLICKSHARE 19/08/2014