Bay Technical Associates DS62 Network Card User Manual


 
DS62-Network, DS62-MD4 Network/Modem Host Module
20
Serial Port Device Name
Select a port and type the new name.
Attention Character
Pressing the Attention Character 5 consecutive times will access the network main menu. The Default
is a semi-colon (;). Select this option to change the attention character. The DS displays the following:
Disconnect Timeguard
This feature ensures reliable binary data transmission by providing a one-second “Timeguard” after the
DS-Series receives the attention character. If more data is received within the delay period, the DS
treats the character as data, not an attention character; thereby preventing unwanted port disconnection.
The Default setting is Disabled.
Connect Port ID Echo
When a user logs into the DS unit the port is identified in the following example:
Select option 1, to disable the echo. The Default setting is Disabled.
Select option 2 to echo the module and port number. (i.e. 3, 2)
Select option 3 to echo the device name. (Device A)
DTR Line Driver Inactive State is: High
High ? (Y/N, CR for no change):
Current device name: EIA-RS232
Enter device name for serial port ((1 - 16 char., CR to end) :
Attention Character is........... ;
Enter Attention Character :
Disconnect Time Guard is.......... Disable
d
Enable ? (Y/N), CR for no change) :
BAYTECH
For further information check:
http://www.baytech.net/
DS62 <= Device name Port echo.
or
02,1 <= Module and Port Number echo.