Bay Technical Associates DS62 Network Card User Manual


 
DS62-Network, DS62-MD4 Network/Modem Host Module
6
Connection Description
BayTech's host communication module provides an interface that controls user access to the DS Series
data switch and other DS Series connected modules.
EIA-232 SERIAL CONNECTION
The DS-Series host communications modules have an RJ-45 port which uses an 8-pin crossed modular
cable to connect to a local EIA-232 device such as a computer terminal or external modem. Most serial
computers do not have RJ-45 connections; therefore an adapter is provided with this unit to convert
from a DE-9 connector to an RJ-45 connector (Bay Tech Part No. 9FRJ45PC-4). An adapter to convert
from a DB-25 connector to an RJ-45 connector is also available from Bay Tech, upon request (Bay
Tech Part No. 25FRJ45PC-4). The 8-pin crossed modular cable is configured to operate with these
adapters.
Internal MODEM CONNECTION
A Flash upgradeable 56 Kbps (V.90bis) modem allows standard dial-up telephone lines to be used
between the Data Switch installation and the user's location.
IMPORTANT: The DS62-MD4 modem option has priority over the EIA-232 serial port. If a serial
port user is in configuration mode or connected to a DS74 I/O port when a modem connection is
established, the serial port user will be “booted” off, allowing the remote user to communicate with the
DS unit. Using the RJ04X007 (RJ-11) modular cable, connect to “LINE” on the DS62-MD4 module to
the Telco wall jack. Using communications software, dial the modem using the ATDT command.
10/100 BASE-T NETWORK PORT CONNECTION
Using a straight 10/100 Base-T cable, connect the RJ-45 port labeled ETHERNET on the HOST
module to an RJ-45 port on the network hub. The LINK (link integrity) LED, located on the front
panel of the HOST, illuminates when a good connection is established between the HOST and the hub.
Installation
UNPACKING
Compare the unit and serial number of the equipment you received to the packing slip located on the
outside of the box. Inspect equipment carefully for damage that may have occurred in shipment. If
there is damage to the equipment or if materials are missing, contact BayTech technical support at 228-
563-7334 or call toll free inside the United States at 800-523-2702. At a minimum, you should receive
the following:
1. The Host Module and DS74 Modules.
2. Manual insert describing the location of the User’s Guide on BayTech’s website at
www.baytech.net.
3. Power Cords that may be attached to the unit (if order requested detachable cords).
4. 1 ea. DE-9 (9 pin) PC com port adapter -- 9FRJ45PC (with Cisco Interface) or 9FRJ45PC-1.
5. 1 ea. RJ-45 Roll over cable -- RJ08X007.
NOTE: Keep the shipping container and packing material in the event future shipment is
required.