Brother 1660e Printer User Manual


 
2001/10/02
CHAPTER 8 BAR CODE CONTROL - 6
Ÿ Line Block Drawing & Box Drawing Shading
“S” 1 = Black
2 = Vertical stripes
3 = Horizontal stripes
4 = Cross hatch
3.3. Bar Code Scaling (Width only)
n = “mnnn” or “Mnnn” (nnn = 0 ~ 32767)
This parameter specifies the bar code width scaling. The unit of "nnn" is %. The default value is m100
(100%).
3.4. Bar Code Human Readable Line On or Off
n = “r0” or “R0” Human readable line OFF
n = “r1” or “R1” Human readable line ON
Default: Human readable line ON when the following barcode types are selected.
(1) “T5” or “t5”
(2) “T6” or “t6”
(3) “T130” or “t130”
(4) “T131” or “t131”
Default: Human readable line OFF
All others
This parameter specifies whether or not the printer prints the human readable line below the bar code. Human
readable characters are always printed with OCR-B font at 10 cpi pitch and all the current character style
enhancements are masked. Note that the default setting is subject to the bar code mode selected by “t” or “T”.
3.5. Quiet Zone
n = “onnn” or “Onnn” (nnn = 0 ~ 32767)
Quiet Zone is the space on both side of the bar codes. Its width can be specified using the units which are set
by the "u" or "U" parameter. ( For the description of "u" or "U" parameter, see the next section.) The
default setting of Quiet Zone width is 1 inch.
3.6. Bar Code, Expanded Character Unit, Line Block Drawing & Box Drawing
Units
n = “u0” or “U0” Millimeters (default)
n = “u1” or “U1” 1/10”
n = “u2” or “U2” 1/100”
n = “u3” or “U3” 1/12”
n = “u4” or “U4” 1/120”
n = “u5” or “U5” 1/10 Millimeter
n = “u6” or “U6” 1/300”
n = “u7” or “U7” 1/720”
This parameter specifies the measurement units of X-axis offset, Y-axis offset and bar code height.