2001/10/02
APPENDIX D REFERENCE LIST OF MX-2000/4000/5000 SERIES UNIQUE COMMANDS - 5
3. COMMAND REFERENCE LIST
This section describes the specific commands as listed below used to support the functions of the Mailbox unit.
1) PJL output tray & mode setting
2) PJL mailbox protection & bin number setting
3) PJL avoidance of output bin full
4) PCL output tray setting
5) PS output tray & mode setting
6) PS mailbox protection & bin number setting
For the details on each command, refer to the following sections.
3.1. Commands Descriptions
3.1.1. PJL output tray & mode setting
Format
@PJL SET/DEFAULT OUTBIN=TrayName
Parameter
TrayName*
• UPPER: Select the printer face-down output tray.
• OPTIONALOUTPUTBIN1: Select the #1 bin of the Mailbox unit.
• OPTIONALOUTPUTBIN2: Select the #2 bin of the Mailbox unit.
• OPTIONALOUTPUTBIN3: Select the #3 bin of the Mailbox unit.
• OPTIONALOUTPUTBIN4: Select the #4 bin of the Mailbox unit.
• OPTIONALOUTPUTBIN5: Select the #5 bin of the Mailbox unit. (except HL-3260)
• OPTIONALOUTPUTBIN6: Select the #6 bin of the Mailbox unit (except HL-3260)
• OPTIONALOUTPUTBIN7: Select the #7 bin of the Mailbox unit. (except HL-3260)
• OPTIONALOUTPUTBIN8: Select the #8 bin of the Mailbox unit. (except HL-3260)
• OPTIONALOUTPUTBIN9: Select the #9 bin of the Mailbox unit. (except HL-3260)
• OPTIONALOUTPUTBIN10: Select the #10 bin of the Mailbox unit. (except HL-3260)
• ALLSTACKER: Select the stacker function. **
• ALLSORTER: Select the sorter function. **
* = The tray names are compatible with the HP tray naming.
** = These are unique tray names (parameters) for the HL-2060/2460/3260.
Default = ALLSTACKER
Explanation
• This command selects the specified output tray and output mode, trays defined as Mailboxes are numbered
from the bottom of the unit upwards
• This command is ignored when there is no specified tray.
• The ALLSTACKER and ALLSORTER parameters are executed for all output trays other than the ones which
are defined and protected as mailboxes. (Refer to Section 3.1.2 ‘PJL mailbox protection & tray number
setting’.)
• The difference between the SET and DEFAULT selection and the effective period of this setting follow the
PJL specifications.