Brother 1660e Printer User Manual


 
2001/10/02
APPENDIX D REFERENCE LIST OF MX-2000/4000/5000 SERIES UNIQUE COMMANDS - 6
3.1.2. PJL mailbox protection & bin number setting
Format
@PJL SET/DEFAULT MAILBOXPROTECT=TrayNumber
Parameter
TrayNumber
<HL-2060/2460>
Lower unit: #1 to 5 from bottom to top
Lower unit + Upper unit: #1 to 10 from bottom to top
<HL-3260>
#1 to 4 from bottom to top
Default = 0
Explanation
This command sets the bins with numbers larger than the TrayNumber specified as mailbox use only. They
cannot then be used for either stacker or sorter functions.
If the bin number is set to 0, the mailbox protection is released, then all bins can be used for stacker and sorter
functions.
If the bin number is set out of the effective range, this command is ignored.
<HL-2060/2460>
Setting type Effective range
MX not installed 0
Lower unit installed 0, 1 5
Lower & upper unit installed 0, 1 10
<HL-3260>
Setting type Effective range
MX not installed 0
MX installed 0, 1 4
The difference between the SET and DEFAULT selection and the effective period of this setting follow the
PJL specifications.
3.1.3. PJL avoidance of mailbox bin full
Command
@PJL SET/DEFAULT AVOIDMAILBOXFULL=ON/OFF
Parameter
ON/OFF
OFF: Paper is ejected to the printer face-down output tray when the specified tray is full.
ON: Paper is not ejected to the printer face-down output tray even when the specified tray is full.
Default = OFF
Explanation
When paper is ejected into a bin specified by a setting command which limits the bin selection, this command
selects whether to eject automatically paper to the printer face-down output tray or not when the specified bin
is full.
The difference between the SET and DEFAULT selection and the effective period of this setting follow the
PJL specifications.