Confidential
3-49
(2) Remove the two bind B M3x8 Taptite screws, and then remove the Density shield plate 1.
Fig. 3-33
(3) Remove the cup S M3x6 Taptite screw, and then remove the Earth plate 2.
Fig. 3-34
Taptite, bind B M3x8
Transfer HVPS PCB unit
Density shield plate 1
Transfer HVPS PCB unit
Taptite, cup S M3x6
Earth plate 2