Selector No. Function Setting and Specifications
1
|
3
Caller ID judgment voltage
(to be distinguished from rings)
(Not used.)
No. 1 2 3
0 0 0: 0 V
0 0 1: 5 V (Default)
0 1 0: 10 V
0 1 1: 15 V
1 0 0: 20 V
1 0 1: 25 V
1 1 0: 30 V
1 1 1: Max.
4
|
6
Caller ID judgment voltage
(to be distinguished from
reverse polarity voltages)
(Not used.)
No. 4 5 6
0 0 0: 0 V
0 0 1: 5 V (Default)
0 1 0: 10 V
0 1 1: 15 V
1 0 0: 20 V
1 0 1: 25 V
1 1 0: 30 V
1 1 1: Max.
7 Not used.
8
Base unit start button after
cordless handset dialing
0: Invalid (Default) 1: Valid
Note:
Selectors 1 through 6 are applicable only to models designed for the European market.
- Selectors 1 through 3: Caller ID judgment voltage (to be distinguished from rings)
(Not used.)
If caller IDs cannot be displayed because of confusion with rings due to variations in the
voltage, increase the judgment voltage.
However, do make sure that the voltage value set by selectors 1 through 3 of this switch is
equal to, or greater than, the value set by selectors 4 through 6 of the same switch.
- Selectors 4 through 6: Caller ID judgment voltage (to be distinguished from reverse
polarity voltages) (Not used.)
If caller IDs cannot be displayed because reverse polarities cannot be detected due to a
large difference between line voltages in a reverse polarity condition and in a steady
condition, increase the judgment voltage.
However, do make sure that the voltage value set by selectors 1 through 3 of this switch is
equal to, or greater than, the value set by selectors 4 through 6 of the same switch.
- Selector 8: Base unit start button after cordless handset dialing
Even if the base unit start button is pressed to start a FAX transmission during calling
when this selector is in its default state, no FAX transmission will occur. By using this
selector, it is possible to make the base unit start button operative after cordless handset
dialing.