Confidential
App. 1-33
< WSW28 >
Selector No. Function Setting and Specifications
1
|
3
Transmission level of DTMF
high-band frequency signal
No. 1 2 3
0 0 0: 0 dB
0 0 1: +1 dB
0 1 0: +2 dB
0 1 1: +3 dB
1 0 0: 0 dB
1 0 1: -1 dB
1 1 0: -2 dB
1 1 1: -3 dB
4
|
6
Transmission level of DTMF
low-band frequency signal
No. 4 5 6
0 0 0: 0 dB
0 0 1: +1 dB
0 1 0: +2 dB
0 1 1: +3 dB
1 0 0: 0 dB
1 0 1: -1 dB
1 1 0: -2 dB
1 1 1: -3 dB
7
8
Not used.
- Selectors 1 through 6: Transmission level of DTMF high-/low-band frequency signal
These selectors are intended for the manufacturer who tests the machine for the Standard.
Never access them.