Troubleshooting and Maintenance 89
MAINTENANCE
3
Pull the toner cartridge out of the drum unit assembly while holding down the lock lever with
your right hand. (See Replacing the Toner Cartridge, page 83.)
4
Wait to unpack the new drum unit until immediately before installing it. Place the old drum unit
into the aluminium bag and discard it according to local regulations.
5
Reinstall the toner cartridge into the new drum unit. (See Replacing the Toner Cartridge, page
83.)
6
Reinstall the new drum unit, keeping the front cover open.
7
Press Clear to reset the drum life counter.
8
Press 1, and when the display shows ACCEPTED
close the front cover.
Discard the used drum unit according to local regulations. Be sure to seal the drum
unit tightly so toner powder does not spill out of the unit. When discarding used
drum units, keep them separate from domestic rubbish.
• If an unpacked drum unit is subjected to excessive direct sunlight or room
light, the unit may be damaged.
• Handle the toner cartridge and the drum unit carefully because they
contain toner. If toner scatters and your hands or clothes get dirty,
immediately wipe or wash with cold water.
• Do not touch the scanner window with your fingers.
Lock
Lever
REPLACE DRUM?
1.YES 2.NO