Brother HL-2400C Series Printer User Manual


 
USER’S GUIDE
4–44
CONTINUE MODE
If any recoverable error occurs including “Toner Empty,” it can be
cleared with the
Continue
button. The
Continue
button function is
selected with this mode setting.
Display Message Continue Mode
CONTINUE=MANUAL Select the manual or auto error recovery
mode. Press the
Continue
button to clear
errors. (Factory setting)
CONTINUE=AUTO Select the auto error recovery mode. The
printer automatically clears recoverable
errors. You need not press the
Continue
button.
SCALABLE FONT
Note
The setting in this mode menu is effective only in the HP PCL5C mode. It
does not appear in any other emulation modes.
Since this printer has many scalable fonts, some application programs
may not be able to handle them correctly. When the HP PCL5C
emulation mode has been selected, the printer may print a different font
rather than the font you have selected with your program (or the font
selection command).
To cope with this font problem, you can restrict the font selection by this
command as follows:
Display Message Scalable Font
FONT=ALL All scalable fonts of this printer can be
selected with the font selection command.
(Factory setting)
FONT=LJ Scalable fonts of this printer other than the
following can be selected with the font
selection command: Atlanta, Bermuda
Script, PC Brussels, Copenhagen,
Germany, Portugal, Calgary, San Diego,
and US Roman.
Even if you restrict the font selection as above, you can select among all
the scalable fonts with the
Font
button. The setting in this mode menu
merely restricts the font selection command from an application.