Brother HL-2400C Series Printer User Manual


 
CHAPTER 5 MAINTENANCE
5-17
Fusing Unit
Fusing Unit
When the following message appears on the LCD panel, you need to
replace the Fusing Unit.
REPLACE FUSER
Warning
The Fusing unit and the parts around it are HOT. Be sure to wait
about 30 minutes and check it has cooled down before you start
replacing the Fusing unit.
If you touch the HOT parts, you might get injured.
!
Caution
When replacing the fusing unit, wait for approximately 30 minutes before
printing after the new unit is installed to allow the fusing oil to circulate
in the new fusing unit.
Replacing the Fusing Unit
1. Press the
Power
button and turn the printer off and unplug the
printer. Wait for 30 minutes or until the printer has cooled down.
2. Open the Top cover and the Rear Access Cover.
3. Unscrew the screws on both sides inside the Rear Access Cover
and release the metal parts.
Fig. 5-18 Unscrew and release the Metal Parts