SmartSwitch 6500 User Guide 8-7
Upgrades and Firmware Upgrading and Changing Firmware
...................................................
Validity checks of the Switch Software Downloaded file...
All Validity checks OK
Programming downloaded image into Switch Software section, please wait...
New Switch Software programmed successfully
=>
9. Check whether the switch download is successful by entering the go command.
8.1.6 Using the Update Firmware Command
You can upgrade the operating firmware of the SmartSwitch 6500 while the switch is running its current firmware.
This procedure is known as a hot upgrade and is accomplished by the
update firmware command.
When the SmartSwitch 6500 is started (or rebooted), it copies its operating firmware from flash RAM to the CPU’s
program memory. When a hot upgrade is performed, the image in flash RAM is erased and replaced with the new
firmware image. While the upgrade is occurring, the switch continues to run its copy in program memory. When the
switch is rebooted, the new firmware image residing in flash RAM is copied into system memory and then run.
To use the hot upgrade feature, the SmartSwitch 6500 must have network access to an end station running TFTP server
software. The SmartSwitch 6500 operating firmware file must reside within the directory specified by the TFTP server
software. Often, this directory is /tftpboot. However, it may be different with your TFTP server software.
The following is an example of a hot upgrade:
Smart6500 # update firmware
ServerIP() : 206.61.237.127
< IP address of TFTP server
Path(public/Smart6500.ima) : builds/luxor2/server.ima
< Path and name of file to download
You are updating the code image in the flash.
Are you sure this is what you want to do?
Confirm(y/n)?:y
< Specify Yes to start download process
Verifying bootfile builds/luxor2/server.ima on 206.61.237.127
...passed.
Erasing Flash.
Using TFTP to get and program bootfile builds/luxor2/server.ima from 206.61.237.127.
4904K (5021760 bytes) received.
Flash update succeeded.
You will have to reboot for the new image to take effect.
Smart6500 #
Notice that the update firmware command does not use Bootp to find the TFTP server. Instead, the update firmware
command requires that you specify the IP address of the TFTP server, the path to the image file, and the file name.
Unsuccessful Update
If the update firmware command fails, DO NOT turn off or attempt to reboot your SmartSwitch 6500 switch. In its
current state, the operating firmware normally stored in flash RAM is erased. The switch is functioning only because
it is running the image of the operating firmware that resides in volatile system memory.
If possible, determine why the
update firmware command failed. Possible causes are: