Cabletron Systems 6500 Switch User Manual


 
SmartSwitch 6500 User Guide v
SAFETY INFORMATION
CLASS 1 LASER TRANSCEIVERS
The IOM-29-4, IOM-29-4-IR, IOM-29-4-LR, IOM-39-1 and IOM-39-1-LR connectors use Class 1 Laser transceivers.
Read the following safety information before installing or operating one of these modules.
The Class 1 Laser transceivers use an optical feedback loop to maintain Class 1 operation limits. This control loop
eliminates the need for maintenance checks or adjustments. The output is factory set, and does not allow any user
adjustment. Class 1 Laser transceivers comply with the following safety standards:
21 CFR 1040.10 and 1040.11 U. S. Department of Health and Human Services (FDA).
IEC Publication 825 (International Electrotechnical Commission).
CENELEC EN 60825 (European Committee for Electrotechnical Standardization).
When operating within their performance limitations, laser transceiver output meets the Class 1 accessible emission
limit of all three standards. Class 1 levels of laser radiation are not considered hazardous.
LASER RADIATION AND CONNECTORS
When the connector is in place, all laser radiation remains within the fiber. The maximum amount of radiant power
exiting the fiber (under normal conditions) is -12.6dBm or 55x10
-6
watts.
Removing the optical connector from the transceiver allows laser radiation to emit directly from the optical port. The
maximum radiance from the optical port (under worst case conditions) is 0.8 W cm
-2
or 8x10
3
W m
-2
sr-1.
Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases
eye hazard. When viewing the output optical port, you must remove power from the network adapter.