Cabletron Systems ZX-250 Switch User Manual


 
SmartCell ZX-250 User Guide B-3
Specifications Technical Specifications
>"•mamV Never pick up the SmartCell ZX-250r by the handles of its power supply.
When only one power supply is installed, a sheet metal blank MUST be installed in place of the missing power supply.
Failing to do so affects the fan’s air flow and may cause overheating and component failure. The blank also must be
installed to maintain EMI integrity.
$•• :'%+2,%"/˜96'%,),%":,329
Table B-2 Power Supply Module Lamps
Lamp Meaning
AC Power OK The power supply is connected to AC line voltage
DC Power OK The power supply is producing DC power for the
switch
Table B-3 Hardware Specifications
Model SmartCell ZX-250i SmartCell ZX-250r
Processor i960CF, 33 MHz i960CF, 33 MHz and R4700
150 mhz
Switching
engine
2.5 Gbps, non-blocking 2.5 Gbps, non-blocking
Switch latency < 11 microseconds < 11 microseconds
CPU/SAR
memory
8 MB 8 MB
CPU-only
memory
32 MB 32 MB
Buffer memory
(cells)
32 K 32 K
flash memory 8 MB 8 MB
Power supplies Single, non-redundant Single or dual, hot swappable