Cabletron Systems ZX-250 Switch User Manual


 
C-6 SmartCell ZX-250 User Guide
MIB, SMI, MIB Files and Internet MIB Hierarchy Agent Support
2p›F Along with the MIBs, the diskette also contains a README file and the release
note.
C.1.7 MIB Exceptions
With the current implementation of MIB files, conformance to ATM standards for the SmartCell ZX-250 ATM switch
includes the following exceptions.
Non-Conformance
U atmInterfaceIlmiVpi — Read-only
U atmInterfaceIlmiVci — Read-only
U aal5VccTable — Not supported
U atmSvcVcCrossConnectRowStatus Set — Not supported
U atmConfigSigType — The values given below are not supported:
ituDss2
atmfBici2Dot0
U znIpAtmClientDDVcType — Accepts only pvc(2) in sets
U lecMulticastSendType — Accepts only best effort (1)
U lecMulticastSendAvgRate — Accepts values only up to 370370
U lecMulticastSendPeakRate — Accepts values only up to 370370
U leArpEntryType — Accepts only staticVolatile (4) and staticNonVolatile (5)
U lesControlTimeout — Read-only
Not Supported
The following MIB objects are not supported. If used, these objects return either the value zero or the message, “Not
supported.”
U atmInterfaceMaxVpcs
U atmInterfaceConfVpcs
U atmInterfaceDs3PlcpTable
U atmInterfaceTCTable
U atmVplTable
U atmVpCrossConnectIndexNext
U atmVpCrossConnectTable
U atmSvcVpCrossConnectTable
U atmSigSupportTable
U atmSigDescrParamTable