COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 5 PICK-UP/FEEDING SYSTEM
5-38 P
9.1.2 Removing the Pickup/Feeding/Separation Rollers
1) Remove the cassette 1/2.
2) Pick the tab [4] of each, and detach the
pickup roller [1], feeding roller [2], and
separation roller [3] in the axial direc-
tion.
When removing the roller, take
care not to soil it with the grease
used on the rail assembly.
When mounting the roller, be
sure to fit it until a click is
heard.
F05-901-04
9.1.3 Removing the Pickup Solenoid
1) Remove the pickup assembly. (p. 5-
37P)
2) Disconnect the connector [1].
3) Remove the screw [2], and detach
pickup solenoid [3].
F05-901-05
[3]
[3]
[2]
[2]
[1]
[1]
[1]
[1]
[4]
[1]
[2]
[3]
[4]