COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 3 STANDARDS AND ADJUSTMENTS
3-7 T
2.2 Mounting the Motor Unit
1) Engage the pulley [2] of the motor unit
[1] with the belt [3].
2) Using two screws [4], mount the motor
unit [1] temporarily.
3) Fit the spring [5] to apply tension to the
belt [3].
4) Check to make sure that the belt [3] is
vertical.
F03-202-01
5) While taking care not to hold the scan-
ning lamp [1] or the reflecting shade
[2], move the No. 1 mirror base [3]
back and forth two to three times to
make a check once again.
F03-202-02
6) Tighten the two screws to secure the
motor unit in place.
[1]
[6]
[2]
[3]
[4]
[5]
[3]
[1]
[2]