COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 5 SERVICE MODE
5-52 T
OFST1-DC
Use it to enter the adjustment value for the primary charging DC offset 1.
Caution If you have replaced the composite power supply PCB, be sure to enter the
settings indicated on the label attached to the new PCB (case).
Range of 0 to 255 (a lower setting generates lighter images)
adjustment
OFST1-AC
Use it to enter the adjustment value for the primary charging AC offset 1.
Caution If you have replaced the composite power supply PCB, be sure to enter the
settings indicated on the label attached to the new PCB (case).
Range of 0 to 255
adjustment
P-AC2
Use it to enter the adjustment value for the primary charging AC component
2 for the image area.
Range of 0 to 255
adjustment
P-AC3
Use it to enter the adjustment value for the primary charging AC component
3 for the image area.
Range of 0 to 255
adjustment
COPIER>ADJUST>HV-PRI