CHAPTER 5 SERVICE MODE
5-68 T
PD-ME
Use it to execute automatic density correction for text mode (to read PD-
DENS output).
Using the Mode
1) While keeping the following in mind, place the PD-DENS output on the
copyboard glass as indicated:
• The printed side must face down.
• The whiter side (lighter; of the 17 gradations) must face the vertical size
plate.
• The output must be placed in relation to the index in the left rear of the
copyboard glass.
2) Select <PD-ME> to highlight, and press the OK key.
3) The scanning lamp goes ON and OFF 13 times, making as many scans
automatically.
• If ‘OK’ is indicated, end the work.
• If ‘NG’ is indicated, discussed under “Standards and Adjustments” in
Chapter 3.
F05-501-06
Place it so that
the printed side
faces down.
PD-DENS output
COPIER>FUNCTION>DENS