DCS 500 Power Supply User Manual


 
Chapter 3 - Handling of Control Panel CDP 31x
IV A 3 - 6 DCS 500B / DCP 500B Operating Instructions
Step Function Press key Display after key is
pressed
1.
To enter the Parameter Mode
Selection
PAR
0 L 0.0 rpm 00
17 RAMP GENERATOR
01 RAMP.[IN]
119.03
2. To select another group.
While holding the key down,
only the group number and
name is displayed. When the
key is released, number, name
and value of the first pin/ pa-
rameter in the group are dis-
played.
0 L 0.0 rpm 00
21 SPEED MEASUREMEN
0 L 0.0 rpm 00
21 SPEED MEASUREMEN
01 TACHOPULS NR
2048
3. To select a element.
While holding the key down,
only the element number and
name, representing a pin/ pa-
rameter, is displayed. When the
key is released the value of the
element is also displayed.
0 L 0.0 rpm 00
21 SPEED MEASUREMEN
02 SPEED MEAS MODE
0 L 0.0 rpm 00
21 SPEED MEASUREMEN
02 SPEED MEAS MODE
EMF SPEED ACT
4. To enter the Pin/Parameter Set-
ting Mode.
ENTER
0 L 0.0 rpm 00
21 SPEED MEASUREMEN
02 SPEED MEAS MODE
[EMF SPEED ACT]
5a.
To change the Parameter
value: (slow change)
(fast change)
0 L 0.0 rpm 00
21 SPEED MEASUREMEN
02 SPEED MEAS MODE
[ANALOG TACHO]
5b.
To change the Pin connection
at first: (group number) --->
then: (element number) --->
of the target.
0 L 0.0 rpm 00
2 ANALOG OUTPUTS
05 AO2.[IN]
[105.02]
6a.
6b.
To send the new value to the
drive.
To cancel the new setting and
keep the original value press
any key before pressing
ENTER.
The selected Keypad Mode is
entered.
ENTER
ACT
PAR
FUNC
DRIVE
0 L 0.0 rpm 00
21 SPEED MEASUREMEN
02 SPEED MEAS MODE
ANALOG TACHO
0 L 0.0 rpm 00
21 SPEED MEASUREMEN
02 SPEED MEAS MODE
EMF SPEED ACT
3ADW000055R0401_DCS500B_Operating Instruction_e_d