Chapter 3 - Handling of Control Panel CDP 31x
DCS 500B / DCP 500B Operating Instructions IV A 3 - 7
3.5 Saving of the Parameters to backup memory
Step Function Press key
Display after key is
pressed
1.
To enter the Parameter Mode
Selection
PAR
0 L 0.0 rpm 00
2 ANALOG OUTPUTS
05 AO2.[IN]
105.01
2. Select group 112.
While holding the arrow down,
only the group name is dis-
played. When the key is re-
leased, number, name and
value of the first parameter in
the group is displayed.
0 L 0.0 rpm 00
112 MAINTENANCE
0 L 0.0 rpm 00
112 MAINTENANCE
01 COMMIS STAT
NOT ACTIVATED
3. Select signal number 02 from
group 112.
While holding the arrow down,
only the signal name and num-
ber are displayed. When the key
is released the value is also dis-
played.
0 L 0.0 rpm 00
112 MAINTENANCE
02 BACKUPSTOREMODE
0 L 0.0 rpm 00
112 MAINTENANCE
02 BACKUPSTOREMODE
NONE
4. Press ENTER to select
BACKUPSTOREMODE.
ENTER
0 L 0.0 rpm 00
112 MAINTENANCE
02 BACKUPSTOREMODE
[NONE]
5. Saving of changed values.
Select Set1 (SAVE MOT1 SET)
or Set2 (SAVE MOT2 SET).
0 L 0.0 rpm 00
112 MAINTENANCE
02 BACKUPSTOREMODE
[SAVE MOT1 SET]
6a.
6b.
Confirmation of the saving.
Saving procedure is completed
when NONE is displayed.
To cancel the saving and keep
the original value press any key
before pressing
ENTER.
The selected Keypad Mode is
entered.
ENTER
ACT
PAR
FUNC
DRIVE
0 L 0.0 rpm 00
112 MAINTENANCE
02 BACKUPSTOREMODE
ERASING...
0 L 0.0 rpm 00
112 MAINTENANCE
02 BACKUPSTOREMODE
NONE