Each Dell system, when operating, is designed to withstand 0.25 G (half-sine wave) at
a sweep of 3 to 200 hertz (Hz) for 15 minutes. In storage, the system can withstand
0.5 G at 3 to 200 Hz for 15 minutes.
3RZHU6RXUFH,QWHUUXSWLRQV
Systems are especially sensitive to variations in voltage supplied by the AC power
source. Over-voltage, undervoltage, and transients (or
spikes
) can erase data from
memory or even cause components to fail. To protect against these types of prob-
lems, power cables should always be properly grounded and one or both of the
following methods should be used:
Use one of the power protection devices described in the following section,
Power Protection Devices.
Place the system on a dedicated power circuit (rather than sharing a circuit with
other heavy electrical equipment). In general, do not allow the system to share a
circuit with any of the following:
Copier machines
Air conditioners
Vacuum cleaners
Space heaters
Power tools
Teletype machines
Adding machines
Laser printers
Facsimile machines
Any other motorized equipment
Besides these appliances, the greatest threat to a systems supply of power are
surges or blackouts caused by electrical storms. Whenever possible, turn off the sys-
tem and any peripherals and unplug them from their power sources during
thunderstorms.
If a blackout occurseven a temporary onewhile the system is turned on, turn off
the system immediately and disconnect it from its power source. Leaving the system
on may cause problems when the power is restored; all other appliances left on in the
area can create large voltage spikes that can damage the system.