Dell 4350 Server User Manual


 
12 Dell PowerEdge 4350 Systems Users Guide
39&
Abbreviation for polyvinyl chloride.
4,&
Abbreviation for quarter-inch cartridge.
5$0
Acronym for random-access memory.
The computers primary temporary stor-
age area for program instructions and
data. Each location in RAM is identified by
a number called a
memory address
. Any
information stored in RAM is lost when you
turn off your computer.
5$,'
Acronym for redundant array of inexpen-
sive disks. This phrase was introduced by
David Patterson, Garth Gibson, and
Randy Katz at the University of California
at Berkeley in 1987. The goal of RAID is
to use multiple small, inexpensive disk
drives to provide high storage capacity
and performance while maintaining or
improving the reliability of the disk
subsystem.
Patterson, Gibson, and Katz described
five different methods, which are known
as RAID levels 1 through 5. Each level
uses one or more extra drives to provide
a means of recovering data lost when a
disk fails, so that the effective failure
rate of the whole disk subsystem be-
comes very low.
Recently, Katz has defined a sixth meth-
od, RAID 6, which improves reliability
even further, and a configuration that pro-
vides no data recovery has popularly
become known as RAID 0.
5$,'
RAID 0 is commonly called
striping
. This
was not originally defined as a RAID level
but has since come into popular use. In
this array configuration, data is written
sequentially across the available disks and
no redundancy is provided. RAID 0 config-
urations provide very high performance
but relatively low reliability. RAID 0 is the
best choice when DSA controller cards
are duplexed. See also striping.
5$,'
RAID 1 is commonly called
mirroring
.
RAID 1 is the best choice in high-availability
applications that require high performance
or relatively low data capacity. See also
mirroring, RAID 10
5$,'
RAID 3 is commonly called
striping.
RAID
3 uses striping with one drive dedicated
to parity to protect data. Data is striped
such that a single transaction requires ac-
cess to all drives. See also striping.
5$,'
RAID 4 is commonly called
guarding
. It
uses data striping, like RAID 3, but adds a
single, dedicated parity drive. The parity
data stored on this drive can be used to
recover data lost from a single failed drive.
RAID 4 configurations write data slowly
because parity data has to be generated
and written to the parity drive, and the
generation of the parity data frequently re-
quires reading data from multiple physical
drives. See also guarding and striping.
5$,'
RAID 5, like RAID 4, is commonly called
guarding
. RAID 5 is identical to RAID 4,
except that the parity data is distributed
evenly across all physical drives instead
of a parity drive. In configurations using a
large number of physical drives in which
a large number of simultaneous small
write operations are being performed,
RAID 5 offers potentially higher perfor-
mance than RAID 4. RAID 4 and RAID 5
configurations are appropriate in high-
availability applications where
performance is less critical or where high
data capacity is required. See also
guarding.
5$,'
RAID 10 is a
mirroring
technique in which
data is duplicated across two identical
RAID 0 arrays or hard-disk drives. All data
on a physical drive in one array is duplicat-
ed, or
mirrored
, on a drive in the second
array. Mirroring offers complete redun-
dancy of data for greater data security.
See also mirroring, RAID 1, and striping.
3502Ebk0.book Page 12 Friday, November 13, 1998 10:00 AM