Dell C2100 Server User Manual


 
18 About Your System
Table 1-9. Fault Indicator Codes
Collecting System Event Log for Investigation
If the front panel LED blinks for 30 to 60 seconds upon applying AC power to
the power supply, the baseboard management controller (iBMC) is
initializing. If not, then the iBMC is not functioning. If the iBMC is working,
try to gather system event log (SEL) information for investigation.
POST Error Codes
Yellow off Power supply is off or AC input
voltage is out of normal operating range
(90–264 VAC).
Blinks green Standby power is on.
Fault Indicator Condition
Blinks amber Host has critical or non-critical events
detected by iBMC, please check iBMC SEL
for details.
Amber off SEL is cleared or fail symptom has been
recovered. This failed LED will be turned
off in power off state.
Code Log in iBMC Error Message Corrective Action
0000 Yes Timer Error
Remove AC power to the system for
10 seconds and restart the system.
If the problem persists, see "Getting
Help" on page 133.
0003 Yes CMOS Battery
Low
See "Troubleshooting the System Battery"
on page 114.
Power Indicator Condition
book.book Page 18 Friday, November 8, 2013 11:29 AM