[4.5-2] Setting the communications parameters for the direct-connect
interface
Selecting "2:CONNECTOR" on the SET COMMUNI-
CATION menu calls up the screen shown at left.
1 PARAMETER: Switches to the commu-
nications parameters set-
ting screen.
2 PROTOCOL: Switches to the commu-
nications protocol screen.
Select a desired screen by using the numerical
keys or
* and * keys, and then press the
ENT key.
To return to the SET COMMUNICATION menu,
press the C key.
(1) Communications parameters setting screen
Selecting "1:PARAMETER" on the SET CONNEC-
TOR screen calls up the screen shown at left.
Highlighted is the current setting.
1 TRANSMIT SPEED: Sets the transmission
speed.
2 PARITY BIT: Sets the vertical parity:
none, odd, or even.
3 DATA: Sets the character length.
4 STOP: Sets the stop bit length.
Select a desired item by using the numerical keys
or
* and * keys. Then select a desired set-
ting by using the
* and * keys.
To return to the SET CONNECTOR screen, press
the C key.
If the BHT-Ir protocol has been selected, the
parity bit, character length, and stop bit length
settings will be ignored.
SET CONNECTOR
1:PARAMETER
2:PROTOCOL
SET PARAMETER
< CONNECTOR >
1:TRANSMIT SPEED:
300 600 1200 2400
4800 9600 19200
38400 57600 115200
2:PARITY BIT : N O E
3:DATA:7 8 4:STOP:1 2