Denso BHT-7000 Scanner User Manual


 
76
Pressing the 3 key while holding down the SF
key on the SYSTEM MENU calls up the screen
shown at left.
1 DOWNLOAD: Downloads the BHT system pa-
rameter file to the user area of
the BHT-7000.
2 UPLOAD: Uploads the BHT system pa-
rameter file stored in the BHT-
7000.
Select a desired item by using the numerical keys
or
* and * keys, then press the ENT key.
Press the C key to return to the SYSTEM MENU.
SYSTEM PARAMETER
1:DOWNLOAD
2:UPLOAD
DOWNLOAD
** Waiting **
DOWNLOAD
__BHT.SYS
** Loading **
XXXXX/YYYYY
DOWNLOAD
__BHT.SYS
** Completed **
[ 8 ] Downloading/Uploading the BHT System Parameter
File
SYSTEM PARAMETER
transfer menu
[8.1] Downloading the BHT system parameter file
Selecting "1:DOWNLOAD" on the SYSTEM PARAM-
ETER menu calls up the screen shown at left. With
this screen displayed, the BHT-7000 waits for the
BHT system parameter file to be downloaded.
While the downloading operation is in progress,
the screen shown at left is displayed indicating the
file name and the number of received records/the
total number of records.
To abort the downloading operation, press the C
key. The screen will switch back to the SYSTEM
PARAMETER menu.
Upon completion of downloading, the BHT-7000
displayed the screen shown at left and beeps once.
Press the C key to return to the SYSTEM PARAM-
ETER menu.
* For BHT-7000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , ,
, and keys, respectively