D-Link DES-3225G Switch User Manual


 
24-port NWay Ethernet Switch User’s Guide
128 Web-Based Network Management
Baud Rate Determines the serial port bit rate that will be used the next time the Switch is restarted. Applies
only when the serial port is being used for out-of-band (SLIP) management; it does not apply when the port is used
for the console port. Available speeds are 2400, 9600, 19,200 and 38,400 bits per second. The default setting in this
Switch version is 9600.
Monitor
This third category includes: Switch Overview, Port Statistics (Traffic, Errors, Packet Analysis, and
Utilization), Browse Address Table, Browse IGMP Status, Browse GVRP Status, Browse GMRP
Status, and Switch History.
Switch Overview
Figure 7-30. Switch Statistics window
The information is described as follows:
Update Interval Choose the desired setting: 2 seconds, 5 seconds, 15 seconds, 30 seconds, 60 seconds or
Suspend.
Port The selected port to be monitored.
TX frames/sec Counts the total number of frames transmitted from a selected port per second since the
Switch was last rebooted.
RX frames/sec Counts all valid frames received on the port per second since the Switch was last rebooted.