Programming Details
MVME3100 Single Board Computer Installation and Use (6806800M28C)
135
The Device Number is as listed when Bus A is in PCI-X mode. If Bus A is in PCI mode, add 0x16
(0b1_0000) to the listed Device Number.
The following table shows the Vendor ID and the Device ID for each of the planar PCI devices on
the MVME3100.
C
(PCI6520-2)
0b0_0000 16 uPD740101
USB
IRQ4 IRQ5 IRQ6
0b0_0100 20 21150 on
PMCSpan
PCI Expansion
(21150)
0b0_0010 18 PMCSpan
Slot 1
IRQ6 IRQ7 IRQ4 IRQ5
0b0_0011 19 PMCSpan
Slot 2
IRQ7 IRQ4 IRQ5 IRQ6
0b0_0100 20 PMCSpan
Slot 3
IRQ4 IRQ5 IRQ6 IRQ7
0b0_0101 21 PMCSpan
Slot 4
IRQ5 IRQ6 IRQ7 IRQ4
Table 7-7 IDSEL and Interrupt Mapping for PCI Devices (continued)
PCI Bus
Device
Number
Field
AD Line
for IDSEL
PCI Device
or Slot Device/Slot INT to MPC8540 Ext IRQ
INTA# INTB# INTC# INTD#
Table 7-8 Planar PCI Device Identification
Function Device Vendor ID Device ID
System Controller MPC8540 0x1057 0x0008
PCI-X-to-PCI-X Bridge PCI6520CB 0x10B5 0x6520
VME Controller TSi148 0x10E3 0x0148
sATA Controller Sil3124A 0x1095 0x3124
USB Controller μPD720101 0x1033 0x0035