Requirements Hardware Preparation and Installation
MVME7100 Single Board Computer Installation and Use (6806800E08A)
31
2.3 Requirements
Make sure that the board, when operated in your particular system configuration, meets the
requirements specified in the next sections.
2.3.1 Environmental Requirements
The following table lists the currently available specifications for the environmental
characteristics of the MVME7100. A complete functional description of the MVME7100
baseboard appears in Chapter 4, Functional Description.
Operating temperatures refer to the temperature of the air circulating around the board
and not to the component temperature.
Table 2-2 MVME7100 Specifications
Characteristics Operating Nonoperating
Operating temperature 0°C to +55°C (32°F to 131°F) entry
air with forced-air cooling
–40°C to +85° C (-40°F to 185°F)
Temperature change +/-0.5° C/min according to NEBS
Standard GR-63-CORE
Relative humidity 5% to 90% noncondensing 5% to 90% noncondesning
Vibration 1 G sine sweep, 5-100 Hz,
horizontal and vertical (NEBS1)
Shock 20 G peak (half sine) 11mSec
Free Fall 100 mm (unpackaged) per GR-63-
CORE
Product Damage
High humidity and condensation on the board surface causes short circuits.
Do not operate the board outside the specified environmental limits.
Make sure the board is completely dry and there is no moisture on any surface before
applying power.