Chapter 5 Printer Commands
))))))))))))))))))))))))))))))))))))))))))))
))))))))))))))))))))))))))))))))))))))))))))
410 Operators Manual 45
5.3.4 REAL-TIME CLOCK
^A ^D Command
30 Change Clock: Use the sequence below to set the time and date of the optional
real-time socket:
^D30 <CR>
HH:MM:SS <CR>
DD/MN/YR/W <CR>
Where the above parameters are defined as:
HH = hours (24 hour format) DD = day
MM = minutes MN = month
SS = seconds YR = last 2 of year
W = day of the week
1 = SUN
2 = MON
3 = TUE
4 = WED
5 = THR
6 = FRI
7 = SAT
The optional clock chip produces a string of data that is accessed through use of a TSN
of 0 and a TSP dependent on the data required of the clock chip.
The data string is shown below...
HH:MM:SS MN/DD/YR XXX DD/MN/YR XXX
...where xxx is the day of the week.
These values should be inserted into the Field parameters for proper clock text access:
Clock Field Parameters
TSN TSP CC DATA
0 1 8 HH:MM:SS
0 10 8 MN/DD/YR
0 19 3 Day of Week
0 23 8 DD/MN/YR
0 32 3 Day of Week
Table 10