Chapter 5 Printer Commands
))))))))))))))))))))))))))))))))))))))))))))
))))))))))))))))))))))))))))))))))))))))))))
410 Operators Manual 93
60 Clears command 61
XX 61 Mark Text Starting Position: ^A designates which text field to start entering
new data. Section 5.3.8.
62 Pre-padded Text: This command is sent after text that is to appear at the
beginning of each field is sent.
63 Text Mode Control: Section 5.3.8.
0 Disable 1 & 2.
1 Enable auto-print mode
2 Clear all previous text upon receiving new data.
3 Enable 1 & 2.
XX 64 Auto Print String Count: ^A tells the printer how many text strings to accept
before printing. Section 5.3.
65 Emulation Control:
0 Disable All.
1 Enable Label Centering. Used only in conjunction with 450 and 460 emulation.
2 Enable 450 Emulation.
3 Enable 1 & 2.
4 Enable 460 Emulation.
5 Enable 1 & 4.
66 66 Initialize Storage Area for Saved Format Files: Used when format files are to
be stored into Ram. Section 5.3.8.
67 Load Graphic Image: See chapter 6.
0 Send single graphic image in four rotations.
1 Send graphic image #1 of 2 in 2 rotations.
2 Send graphic image #2 of 2 in 2 rotations.
70 Clear commands 71-76.
71 Disable Copies Function.
72 Enable Copies Function.
XX 73 Load copies count: Tells the printer to print a group of labels. Will not increment
serial numbers (use ^D75).
1 74 Infinity Print: Prints a batch of labels like ^D75 but will continue to print until the
machine is turned off.
XX 75 Load Label Count: Tells the printer to print a batch of labels using the serial
number function if enabled.