Epson 410 Printer User Manual


 
Printer Commands Chapter 5
))))))))))))))))))))))))))))))))))))))))))))
))))))))))))))))))))))))))))))))))))))))))))
410 Operators Manual58
^A ^D Command
56 End of Label Fields: Select RAM format label.
57 Enter Label Format Mode: This tells the printer that information for a label is
following
65 Emulation control: This list of commands was designed for those users who
were previously using an older Microcom Corporation printer and now want to use
their old format files with the model 410 printer. Label centering creates an X
offset for the older formats that were left justified. It will not center all the fields on
the label. It offsets a previously left justified label. (Note: Not recommended for
new formats.)
0 Disable All.
1 Enable Label Centering. Used only in conjunction with 450 and 460 emulation.
2 Enable 450 Emulation.
3 Enable 1 & 2.
4 Enable 460 Emulation.
5 Enable 1 & 4.
67 Load Graphic Image: See chapter 6 for more details.
0 Send single graphic in four rotations.
1 Send graphic #1 of 2 in 2 rotations.
2 Send graphic #2 of 2 in 2 rotations.
93 Load Control Code Recognition Status: Some mainframe, mini-computer,
and special-purpose computers cannot send ASCII characters under 20 hex or
send these numbers for reasons other than 410 operation (spooler initialization,
etc). In order to maintain proper flow control, the 410 printer will ignore everything
under 20 hex if so directed. There is also an EEPROM dip switch (see section
5.3) that will enable the printer to enter this mode upon power-up. (Note: if control
code recognition is disabled, the printer will not process the 1Bhex (ESC)
character and therefore will not be able to store data streams.)
0 Enable control code recognition.
1 Disable control code recognition.