Epson C I - 4 0 8 0 All in One Printer User Manual


 
Configuring the printer
3-17
Main-Function INSTALLATION
S Sub-Function INTERFACE
The factory settings for the interface type are: Shared, 8 Kbyte Buffer, 8 bit
word length, even parity bit, 9600 baud, and DTR protocol.
S BUFFER
Buffer size in Kbyte. The maximum size is 30 Kbyte.
S WORD LENGTH
Length of the data to be transferred; values are 7 or 8 bit.
S I/F TYPE (Interface Type)
the following types are available:
S Parallel
S Serial
S Shared
In case the SHARED interface type is selected the printer switches
automatically between the parallel and serial interface. The first data
received at the port determine which interface port becomes active. The
other interface port will be closed so that only one interface is active at a
time (for detailed information see Appendix A Interface Description).
S BAUD RATE (only indicated if the serial interface is selected)
Controls the speed of data transfer. The possible transfer rates are: 600,
1200, 2400, 4800, 9600 or 19200 bps.
S PARITY BIT (only indicated if the serial interface is selected)
The data transfer will be checked by an even or odd parity bit. The values are:
EVEN, ODD, NONE or IGNORE.
S PROTOCOL (only indicated if the serial interface is selected)
Selectable are: DTR, XON/XOFF, or XON/XOFF + DTR.