EverFocus EFC--02-1-A Network Card User Manual


 
59
Press
ENT
to clear the alarm. If system is currently armed user will be prompted to
disarm the system first. Please refer to previous section for how to disarm the system.
Arm/Disarm the System using a Reader
The whole system can also be armed and disarmed using a keypad reader. (The
reader must have an integrated keypad, and the keypad and system reader settings
must be enabled on the controller in order to utilize this feature. Please refer to
subsection “Reader Setting” for instructions on enabling these features.) The part
number for the EverAccess keypad reader is ERK-871.
The user must first enter a command to get into the arm operation mode. (The
command is introduced in step 1 below.) In the arm operation mode, the yellow
LED on the ERK-871 will show the four different system modes outlined below:
Yellow LED Status System ARM Status
OFF Indicates that the system is disarmed
ON Indicates that the system is armed
Flashing Slowly Indicates that the system is in arm delay period
Flashing Quickly Indicates that the system is armed and some alarm
input has triggered the alarm output.
The steps to arm or disarm the system at a keypad reader are as follows:
1. Press
followed by the 6-pin ARM PIN. Press
again
2. The reader is now in the arm operation mode.
3. If the system is in disarmed mode (the yellow LED is OFF), press to
arm the system. The system will enter the arm delay period (the yellow LED
will slowly flash).
Note: The system will not enter the arm delay period, if an alarm input is
active when the user attempts to arm the system. In other words, after
is pressed, if the yellow LED remains off, the system cannot
enter the arm delay period because an alarm input is active.
If the system is in armed mode (the yellow LED is ON) or in the arm delay
period (the yellow LED is flashing slowly), press to disarm the system.
Then the system will enter the disarmed mode (the yellow LED will be off).
If the system is in alarm triggered mode (the yellow LED is flashing quickly),
press to clear the alarm. Then the system will get into the armed mode
(the yellow LED will be on)
1
# 0 0 1
1
1
1
# #