Fujitsu BX600 S2 Server User Manual


 
104 PRIMERGY BX600 S2 Basic Unit
Port Assignment Ethernet Pass-Thru Blade
© cognitas. Gesellschft für Technik-Dokumentation mbH 2007 Pfad: H:\windows\_projekte\Bxz\Betriebsanleitung\Version_Maerz-2007\Archiv\BX600S2_en\blade-us.k11
The following figure illustrates the assignment of the LAN ports of the Ethernet
LAN Pass-Thru-Blades in slots NET3 and NET4 to the channels of the Gigabit
Ethernet I/O modules (daughter cards) of the server blades in a configuration
with five 4-way server blades.
Figure 57: Port assignment to the Gigabit Ethernet I/O modules with five 4-way server blades
9.3 Replacing an Ethernet Pass-Thru Blade
V CAUTION!
Ethernet pass-thru-blades must always be installed in slots NET1 and
NET3 first (see page 101).
An Ethernet LAN Pass-Thru-Blade is installed and removed in the same way as
a LAN switch blade (see section “Installing a LAN Switch Blade” on page 93).
Server
ABABABABABABABABABAB
blade 1
Server
blade 2
Server
blade 3
Server
blade 4
Server
blade 5
Gigabit Ethernet
123
45678910
pass-thru blade 3
I/O module 1
I/O module 2
123
45678910
Gigabit Ethernet
pass-thru blade 4
I/O module 1
I/O module 2
I/O module 1
I/O module 2
I/O module 1
I/O module 2
I/O module 1
I/O module 2