Important Notes Components With Electrostatic-Sensitive Devices
3.2 Components With Electrostatic-Sensitive
Devices
Electrostatic-sensitive components are identified by the following sticker:
Figure 2: ESD label
When you handle components fitted with ESDs, you must observe the following
points under all circumstances:
Always discharge static build-up (e.g. by touching a grounded object) before
working.
The equipment and tools you use must be free of static charge.
Always hold components with ESDs by their edges.
Do not touch any exposed pins or conductors on a component.
Use a grounding cable designed for this purpose to connect yourself to the
system unit as you install components.
Place all components on a static-proof base.
I You will find a detailed description of how to handle ESD components in
the relevant European or international standards (EN 61340-5-1,
ANSI/ESD S20.20).
3.3 CE Certificate
The shipped version of this device complies with the requirements
of the EEC directives 89/336/EEC “Electromagnetic compatibility”
and 73/23/EEC “Low voltage directive”. The device therefore
qualifies for the CE certificate (CE=Communauté Européenne).