Fujitsu BX600 S2 Server User Manual


 
114 PRIMERGY BX600 S2 Basic Unit
Control and Connection Panel FC Pass-Thru Blade
© cognitas. Gesellschft für Technik-Dokumentation mbH 2007 Pfad: H:\windows\_projekte\Bxz\Betriebsanleitung\Version_Maerz-2007\Archiv\BX600S2_en\blade-us.k10
11.1 Control and Connection Panel
Figure 65: FC pass-thru blade control connection panel
The following indicator and connection elements are provided:
The following table shows the conditions of the Fibre Channel ports indicated by
the LEDs.
a Fibre Channel active indicator (green LED)
b Fibre Channel link indicator (amber LED)
c Fibre Channel SFP connector
Slot for Fibre Channel SFP module (see page 115). The slot numbers are assigned to
the server blade slots on the front of the BX600 S2 system (see figure 29 on page 72).
Fibre Channel condition a b
Power ON ON ON
Fibre Channel is online ON OFF
Signal acquired OFF ON
Loss off synchronization ON Blinks
!
#
%
'
&
$
"
ab c